DTSD1352/C 3 Phase Modbus RTU RS485 Din Rail Smart Energy Meter


● IEC62053-21、IEC62053-22


● Din rail mounted


● kWh: Class 0.5S,kVarh:Class 2


● AC 3×220/380V,3×380V,3×57.7/100V,3×100V


● 3×1(6)A,3×10(80)A


● U、I、P、Q、S、PF、kWh、kvarh


● RS485(MODBUS-RTU)

Email: [email protected]

Mobile: +86 134 8217 7205

Whatsapp/Wechat: +86 134 8217 7205

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us

DTSD1352/C dual source meter also called ADL3000-E is a smart meter designed for power supply system, industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation.  DTSD1352 can be used in all kinds of control systems, SCADA systems and energy management systems. All meters meet the related technical requirements of electronic power meter in the IEC62053-21、IEC62053-22 standards.


Voltage Reference voltage 3×220/380V,3×380V,3×57.7V/100V,3×100V,3×380/660V,3×660V
Reference Frequency 50Hz
Consumption <2VA(Single phase)
Current Input current Outlay transformer:3×1.5(6)A、3×20(100)AInlay transformer:3×1.5(6)A
Starting current Outlay transformer:1‰Ib(3×1.5(6)A)、4‰Ib(3×20(100)A)Inlay transformer:1‰Ib
Consumption <1VA (Maximum current)
Measure performance Conform to the standard GB/T 17215.321-2008 GB/T 17215.322-2008 GB/T 17215.323-2008
Accuracy class Outlay transformer:Active energy(Accuracy class:0.5s), reactive energy(Accuracy class 2)(3×1.5(6)A)Active energy(Accuracy class:1), reactive energy(Accuracy class 2)(3×20(100)A)Inlay transformer:Active energy(Accuracy class:0.5s), reactive energy(Accuracy class 2)
The clock precision ≤0.5s/d
pulse The pulse width 80ms±20ms
Pulse constant Outlay transformer:6400imp/kWh(3×1.5(6)A)400imp/kWh(3×20(100)A)Inlay transformer:6400imp/kWh
Communication interface RS485(A+、B-)
medium Shielded twisted pair
agreement MODBUS-RTU


1


① Seal for Anti theft
② Brand
③ Panel
④ Enter-wire
⑤ Auxiliary function
⑥ Pulse output light
⑦ Button
⑧ Outlet wire


Functions


Communication
RS485(Modbus-RTU)
Rated U and I
AC 3×100V, 3×380V, 3×57.7/100V, 3×220/380V; 3×1(6)A, 3×10(80)A
Accuracy
kWh: Class 0.5S,kVarh:Class 2
Frequency
50/60HZ(Optional),range: 45~65HZ
Display
8 digits LCD display U, I, P, Q, PF, kWh and other energy consumption, Power measure (999999.99kWh)
Pulse output
Pulse output kWh/kvarh



3

Consumption
<10VA(Single phase)
Installation
DIN 35mm
Dimension(L*W*H)
126.5*88*69.5mm
Switch relay
Magnetic latching relay(ADL3000-E build-in)
Clock
≤0.5s/d
Starting current
Direct connect: 0.004Ib
Connect via CT: 0.001In



Wiring


4

5


Dimension & Installation



6


7


8


Package


PACKAGE
PHOTOS
9 10

MINIMUM

PACKAGE

Package dimensions(1 PC)
170*150*130mm
MINIMUM PACKAGE Net Weight(1 PC)
0.254KG


ATTENTION !
The above packing and weight data are only refer to model ADL3000-E three phase electronic meter.
For other models or optional functions, please contact the salesman for details, thank you for your cooperation!




VoltageReference voltage3×220/380V,3×380V,3×57.7V/100V,3×100V,3×380/660V,3×660V
Reference Frequency50Hz
Consumption<2VA(Single phase)
CurrentInput currentOutlay transformer:3×1.5(6)A、3×20(100)AInlay transformer:3×1.5(6)A
Starting currentOutlay transformer:1‰Ib(3×1.5(6)A)、4‰Ib(3×20(100)A)Inlay transformer:1‰Ib
Consumption<1VA (Maximum current)
Measure performanceConform to the standardGB/T 17215.321-2008 GB/T 17215.322-2008 GB/T 17215.323-2008
Accuracy classOutlay transformer:Active energy(Accuracy class:0.5s), reactive energy(Accuracy class 2)(3×1.5(6)A)Active energy(Accuracy class:1), reactive energy(Accuracy class 2)(3×20(100)A)Inlay transformer:Active energy(Accuracy class:0.5s), reactive energy(Accuracy class 2)
The clock precision≤0.5s/d
pulseThe pulse width80ms±20ms
Pulse constantOutlay transformer:6400imp/kWh(3×1.5(6)A)400imp/kWh(3×20(100)A)Inlay transformer:6400imp/kWh
CommunicationinterfaceRS485(A+、B-)
mediumShielded twisted pair
agreementMODBUS-RTU