AHKC-EKB Hall Sensor


● Measurement:AC, DC, pulse and other complex current

● Small package size

● Low power consumption

● Extended measuring range

Email: [email protected]

Mobile: +86 134 8217 7205

Whatsapp/Wechat: +86 134 8217 7205

  • Overview
  • Parameter
  • Certificates
  • Customer Questions & Answers
  • Contact us

Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.



Dimension



3-1

Size Dimensions Aperture Installing Dimensions
Specification W H D a e Dia. M N
AHKC - EKA 60 64 16 / / 20 47 /
AHKC - EKAA 60 64 16 / / 20 47 /
AHKC - EKDA 60 64 16 / / 20 47 /
AHKC - EKB 100 102 24 / / 40 80 /
AHKC - EKBA 100 102 24 / / 40 80 /
AHKC - EKBDA 100 102 24 / / 40 80 /
AHKC - EKC 115 110 27 / / 55 95.5 /
AHKC - EKCA 115 110 27 / / 55 95.5 /
AHKC - EKCDA 115 110 27 / / 55 95.5 30
AHKC - K 127 63 25 64 16 / / 30
AHKC - KAA 127 63 25 64 16 / / 30
AHKC - KDA 127 63 25 64 16 / / 46
AHKC - H 149 79 25 82 32 / / 60
AHKC - KA 176 95.5 29 104 36 / / 80
AHKC - HB 204 111.5 29 132 52 / / 48*2
AHKC - HBAA 204 111.5 29 132 52 / / 48*2
AHKC - HBDA 204 111.5 29 132 52 / / 48*2
Parameters Index
Rated Input Current 0~±(50-1000)A
Rated Output Voltage ±5V/±4V
Accuracy Class 1.0
Power Voltage DC±12V(allowable fluctuation±20%)
Zero Offset Voltage ±20mV
Offset Voltage Drift ≤±1.0mV/℃
Linearity ≤0.2%FS
Response Time ≤5us
Bandwidth 0~20kHz
Isolation Voltage 3.5kV/50Hz/1min
Operating Temperature -40℃~85℃
Storage Temperature -40℃~85℃
Consumption ≤0.5W


Specification Ratio Current Power  Supply Output Aperture ( mm ) Accuracy
AHKC - EKA 0-(20-500) A ±15V/12V 5V/4V 20 1 Class
AHKC - EKAA DC 0-(50-500) A 12V/24V 4-20mA 20 1 Class
AHKC - EKDA AC 0-(50-500) A 12V/24V 4-20mA 20 1 Class
AHKC - EKB 0-(200-1000) A ±15V/12V 5V/4V 40 1 Class
AHKC - EKBA DC 0-(200-1000) A 12V/24V 4-20mA 40 1 Class
AHKC - EKBDA AC 0-(200-1000) A 12V/24V 4-20mA 40 1 Class
AHKC - EKC 0-(500-1500) A ±15V/12V 5V/4V 55 1 Class
AHKC - EKCA DC -(500-1500) A 12V/24V 4-20mA 55 1 Class
AHKC - EKCDA AC 0-(500-1500) A 12V/24V 4-20mA 55 1 Class
AHKC - K 0-(400-2000) A ±15V/12V 5V/4V 64*16 1 Class
AHKC - KAA DC 0-(400-2000) A 12V/24V 4-20mA 64*16 1 Class
AHKC - KDA AC 0-(400-2000) A 12V/24V 4-20mA 64*16 1 Class
AHKC - H 0-(500-3000) A ±15V/12V 5V/4V 82*32 1 Class
AHKC - KA 0-(500-5000) A ±15V/12V 5V/4V 104*36 1 Class
AHKC - HB 0-(2000-20000) A ±15V/12V 5V/4V 132*52 1 Class
AHKC - HBAA DC 0-(2000-20000) A 12V/24V 4-20mA 132*52 1 Class
AHKC - HBDA AC 0-(2000-20000) A 12V/24V 4-20mA 132*52 1 Class


Installation



4-1





Wiring



4-2



Precautions


● When the Hall sensor is used, attention must be paid to the coupling between the primary side coil and assistant side coil in order to get better dynamic characteristics and sensitivity, single conductor that should cram the thread hole of Hall sensor module completely is proposed to use.

● When the Hall sensor is used, the best measuring accuracy can be got under rated input current value. When the measured current is much less than the rated value, the primary side can use multi-turns if want to obtain the best accuracy, that is IpNp=rated ampere-turns. In addition, the temperature of the primary side feeder line cannot be more than 80℃.

● When the Hall current sensor is working normally, the auxiliary power supply cannot be more than ±20% of calibration value.

● The Hall Current sensor is strictly prohibited to be fallen from high place (≥1m) during installation and use.

● Zero and full scale regulator potentiometer can not be adjusted.

● Auxiliary power supply is required to be deployed voluntarily.

● Power positive and negative poles cannot be inversely connected.




Package


PACKAGE
PHOTOS
4-3 4-4

MINIMUM

PACKAGE

Package dimensions(1 PC)
18*17*9.5cm
MINIMUM PACKAGE Pakage Weight(1 PC)
0.3Kg


ATTENTION !
The above packing and weight data are only refer to model AHKC-EKB.
For other models or optional functions, please contact the salesman for details, thank you for your cooperation!

ParametersIndex
Rated Input Current0~±(50-1000)A
Rated Output Voltage±5V/±4V
Accuracy Class1.0
Power VoltageDC±12V(allowable fluctuation±20%)
Zero Offset Voltage±20mV
Offset Voltage Drift≤±1.0mV/℃
Linearity≤0.2%FS
Response Time≤5us
Bandwidth0~20kHz
Isolation Voltage3.5kV/50Hz/1min
Operating Temperature-40℃~85℃
Storage Temperature-40℃~85℃
Consumption≤0.5W


SpecificationRatio CurrentPower  SupplyOutputAperture ( mm )Accuracy
AHKC - EKA0-(20-500) A±15V/12V5V/4V201 Class
AHKC - EKAADC 0-(50-500) A12V/24V4-20mA201 Class
AHKC - EKDAAC 0-(50-500) A12V/24V4-20mA201 Class
AHKC - EKB0-(200-1000) A±15V/12V5V/4V401 Class
AHKC - EKBADC 0-(200-1000) A12V/24V4-20mA401 Class
AHKC - EKBDAAC 0-(200-1000) A12V/24V4-20mA401 Class
AHKC - EKC0-(500-1500) A±15V/12V5V/4V551 Class
AHKC - EKCADC -(500-1500) A12V/24V4-20mA551 Class
AHKC - EKCDAAC 0-(500-1500) A12V/24V4-20mA551 Class
AHKC - K0-(400-2000) A±15V/12V5V/4V64*161 Class
AHKC - KAADC 0-(400-2000) A12V/24V4-20mA64*161 Class
AHKC - KDAAC 0-(400-2000) A12V/24V4-20mA64*161 Class
AHKC - H0-(500-3000) A±15V/12V5V/4V82*321 Class
AHKC - KA0-(500-5000) A±15V/12V5V/4V104*361 Class
AHKC - HB0-(2000-20000) A±15V/12V5V/4V132*521 Class
AHKC - HBAADC 0-(2000-20000) A12V/24V4-20mA132*521 Class
AHKC - HBDAAC 0-(2000-20000) A12V/24V4-20mA132*521 Class
Customer Questions & Answers
  • Question:

    Who are we?

    Answer:

    We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc. Our Products: AC/DC electricity meters, current transformers, hall sensors, IOT platform, etc. As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.

    marry August 25, 2022
  • Answer:

    Always a pre-production sample before mass production; Always final Inspection before shipment;

    marry August 25, 2022
  • Answer:

    AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature Monitoring, Residual Current Relay, IOT Platform, etc.

    marry August 25, 2022
  • Answer:

    147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.

    marry August 25, 2022
  • Answer:

    Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc. Accepted Payment Currency: USD, EUR, RMB, etc. Accepted Payment Type: T/T, L/C, etc. Language Spoken:English, Spanish, Chinese, etc.

    marry August 25, 2022
Your Name
E-mail *
Phone/Whatsapp
Country
Your identity (dealer or individual)
Your Inquiry *
Clicky