AHKC-EKB Hall Sensor
● Measurement:AC, DC, pulse and other complex current
● Small package size
● Low power consumption
● Extended measuring range
- Overview
- Parameter
- Certificates
- Customer Questions & Answers
- Contact us
Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.
Dimension
Size | Dimensions | Aperture | Installing Dimensions | |||||
Specification | W | H | D | a | e | Dia. | M | N |
AHKC - EKA | 60 | 64 | 16 | / | / | 20 | 47 | / |
AHKC - EKAA | 60 | 64 | 16 | / | / | 20 | 47 | / |
AHKC - EKDA | 60 | 64 | 16 | / | / | 20 | 47 | / |
AHKC - EKB | 100 | 102 | 24 | / | / | 40 | 80 | / |
AHKC - EKBA | 100 | 102 | 24 | / | / | 40 | 80 | / |
AHKC - EKBDA | 100 | 102 | 24 | / | / | 40 | 80 | / |
AHKC - EKC | 115 | 110 | 27 | / | / | 55 | 95.5 | / |
AHKC - EKCA | 115 | 110 | 27 | / | / | 55 | 95.5 | / |
AHKC - EKCDA | 115 | 110 | 27 | / | / | 55 | 95.5 | 30 |
AHKC - K | 127 | 63 | 25 | 64 | 16 | / | / | 30 |
AHKC - KAA | 127 | 63 | 25 | 64 | 16 | / | / | 30 |
AHKC - KDA | 127 | 63 | 25 | 64 | 16 | / | / | 46 |
AHKC - H | 149 | 79 | 25 | 82 | 32 | / | / | 60 |
AHKC - KA | 176 | 95.5 | 29 | 104 | 36 | / | / | 80 |
AHKC - HB | 204 | 111.5 | 29 | 132 | 52 | / | / | 48*2 |
AHKC - HBAA | 204 | 111.5 | 29 | 132 | 52 | / | / | 48*2 |
AHKC - HBDA | 204 | 111.5 | 29 | 132 | 52 | / | / | 48*2 |
Parameters | Index |
Rated Input Current | 0~±(50-1000)A |
Rated Output Voltage | ±5V/±4V |
Accuracy Class | 1.0 |
Power Voltage | DC±12V(allowable fluctuation±20%) |
Zero Offset Voltage | ±20mV |
Offset Voltage Drift | ≤±1.0mV/℃ |
Linearity | ≤0.2%FS |
Response Time | ≤5us |
Bandwidth | 0~20kHz |
Isolation Voltage | 3.5kV/50Hz/1min |
Operating Temperature | -40℃~85℃ |
Storage Temperature | -40℃~85℃ |
Consumption | ≤0.5W |
Specification | Ratio Current | Power Supply | Output | Aperture ( mm ) | Accuracy |
AHKC - EKA | 0-(20-500) A | ±15V/12V | 5V/4V | 20 | 1 Class |
AHKC - EKAA | DC 0-(50-500) A | 12V/24V | 4-20mA | 20 | 1 Class |
AHKC - EKDA | AC 0-(50-500) A | 12V/24V | 4-20mA | 20 | 1 Class |
AHKC - EKB | 0-(200-1000) A | ±15V/12V | 5V/4V | 40 | 1 Class |
AHKC - EKBA | DC 0-(200-1000) A | 12V/24V | 4-20mA | 40 | 1 Class |
AHKC - EKBDA | AC 0-(200-1000) A | 12V/24V | 4-20mA | 40 | 1 Class |
AHKC - EKC | 0-(500-1500) A | ±15V/12V | 5V/4V | 55 | 1 Class |
AHKC - EKCA | DC -(500-1500) A | 12V/24V | 4-20mA | 55 | 1 Class |
AHKC - EKCDA | AC 0-(500-1500) A | 12V/24V | 4-20mA | 55 | 1 Class |
AHKC - K | 0-(400-2000) A | ±15V/12V | 5V/4V | 64*16 | 1 Class |
AHKC - KAA | DC 0-(400-2000) A | 12V/24V | 4-20mA | 64*16 | 1 Class |
AHKC - KDA | AC 0-(400-2000) A | 12V/24V | 4-20mA | 64*16 | 1 Class |
AHKC - H | 0-(500-3000) A | ±15V/12V | 5V/4V | 82*32 | 1 Class |
AHKC - KA | 0-(500-5000) A | ±15V/12V | 5V/4V | 104*36 | 1 Class |
AHKC - HB | 0-(2000-20000) A | ±15V/12V | 5V/4V | 132*52 | 1 Class |
AHKC - HBAA | DC 0-(2000-20000) A | 12V/24V | 4-20mA | 132*52 | 1 Class |
AHKC - HBDA | AC 0-(2000-20000) A | 12V/24V | 4-20mA | 132*52 | 1 Class |
Installation
Wiring
Precautions
● When the Hall sensor is used, attention must be paid to the coupling between the primary side coil and assistant side coil in order to get better dynamic characteristics and sensitivity, single conductor that should cram the thread hole of Hall sensor module completely is proposed to use.
● When the Hall sensor is used, the best measuring accuracy can be got under rated input current value. When the measured current is much less than the rated value, the primary side can use multi-turns if want to obtain the best accuracy, that is IpNp=rated ampere-turns. In addition, the temperature of the primary side feeder line cannot be more than 80℃.
● When the Hall current sensor is working normally, the auxiliary power supply cannot be more than ±20% of calibration value.
● The Hall Current sensor is strictly prohibited to be fallen from high place (≥1m) during installation and use.
● Zero and full scale regulator potentiometer can not be adjusted.
● Auxiliary power supply is required to be deployed voluntarily.
● Power positive and negative poles cannot be inversely connected.
Package
PACKAGE PHOTOS |
||
MINIMUM PACKAGE |
Package dimensions(1 PC) 18*17*9.5cm |
|
MINIMUM PACKAGE |
Pakage Weight(1 PC) 0.3Kg |
ATTENTION !
The above packing and weight data are only refer to model AHKC-EKB.
For other models or optional functions, please contact the salesman for details, thank you for your cooperation!
Parameters | Index |
Rated Input Current | 0~±(50-1000)A |
Rated Output Voltage | ±5V/±4V |
Accuracy Class | 1.0 |
Power Voltage | DC±12V(allowable fluctuation±20%) |
Zero Offset Voltage | ±20mV |
Offset Voltage Drift | ≤±1.0mV/℃ |
Linearity | ≤0.2%FS |
Response Time | ≤5us |
Bandwidth | 0~20kHz |
Isolation Voltage | 3.5kV/50Hz/1min |
Operating Temperature | -40℃~85℃ |
Storage Temperature | -40℃~85℃ |
Consumption | ≤0.5W |
Specification | Ratio Current | Power Supply | Output | Aperture ( mm ) | Accuracy |
AHKC - EKA | 0-(20-500) A | ±15V/12V | 5V/4V | 20 | 1 Class |
AHKC - EKAA | DC 0-(50-500) A | 12V/24V | 4-20mA | 20 | 1 Class |
AHKC - EKDA | AC 0-(50-500) A | 12V/24V | 4-20mA | 20 | 1 Class |
AHKC - EKB | 0-(200-1000) A | ±15V/12V | 5V/4V | 40 | 1 Class |
AHKC - EKBA | DC 0-(200-1000) A | 12V/24V | 4-20mA | 40 | 1 Class |
AHKC - EKBDA | AC 0-(200-1000) A | 12V/24V | 4-20mA | 40 | 1 Class |
AHKC - EKC | 0-(500-1500) A | ±15V/12V | 5V/4V | 55 | 1 Class |
AHKC - EKCA | DC -(500-1500) A | 12V/24V | 4-20mA | 55 | 1 Class |
AHKC - EKCDA | AC 0-(500-1500) A | 12V/24V | 4-20mA | 55 | 1 Class |
AHKC - K | 0-(400-2000) A | ±15V/12V | 5V/4V | 64*16 | 1 Class |
AHKC - KAA | DC 0-(400-2000) A | 12V/24V | 4-20mA | 64*16 | 1 Class |
AHKC - KDA | AC 0-(400-2000) A | 12V/24V | 4-20mA | 64*16 | 1 Class |
AHKC - H | 0-(500-3000) A | ±15V/12V | 5V/4V | 82*32 | 1 Class |
AHKC - KA | 0-(500-5000) A | ±15V/12V | 5V/4V | 104*36 | 1 Class |
AHKC - HB | 0-(2000-20000) A | ±15V/12V | 5V/4V | 132*52 | 1 Class |
AHKC - HBAA | DC 0-(2000-20000) A | 12V/24V | 4-20mA | 132*52 | 1 Class |
AHKC - HBDA | AC 0-(2000-20000) A | 12V/24V | 4-20mA | 132*52 | 1 Class |
-
Manual
Customer Questions & Answers
-
Question:
Who are we?
Answer:We are a top manufacturer with over 1500 employees, over 300 R&D engineers in China, with CE, ROHS, IEC, EAC, MID, UL, FCC Certificates, etc. Our Products: AC/DC electricity meters, current transformers, hall sensors, IOT platform, etc. As a top-level provider of electrical solution service, we can help you save energy, reduce cost, improve energy efficiency and safety, realize intelligent, visual and fine management of energy, and provide data services for energy management.
marry August 25, 2022 -
Question:
How can we guarantee quality?
Answer:Always a pre-production sample before mass production; Always final Inspection before shipment;
marry August 25, 2022 -
Question:
What can you buy from us?
Answer:AC/DC Energy Meter, Hall Effect Sensor, Current Transformer, Current Transducer, Motor Protectors, Wireless Temperature Monitoring, Residual Current Relay, IOT Platform, etc.
marry August 25, 2022 -
Answer:
147 computer software copyrights, 2 million meters, 1.5 million transformers, more than 100 design patents, 70 utility model patents.
marry August 25, 2022 -
Question:
What services can we provide?
Answer:Accepted Delivery Terms: FOB, CFR, CIF, EXW, DDU, Express Delivery, etc. Accepted Payment Currency: USD, EUR, RMB, etc. Accepted Payment Type: T/T, L/C, etc. Language Spoken:English, Spanish, Chinese, etc.
marry August 25, 2022